什么是钠电池的强制放电测试?

What is the forced discharge test for sodium-ion batteries?

强制放电是 UN38.3 T8 电气滥用测试,模拟电池接线错误、电控故障造成深度过放的极端场景,评估过放后热安全表现。满电电芯外接标准固定负载电阻,持续强制放电至电压归零并保持放电 90 分钟,实时监测外壳温度变化。深度过放会破坏负极 SEI 膜,钠离子不可逆大量析出,内部副反应持续放热,存在鼓包起火风险。测试合格判定:全程无燃烧爆炸,电芯最高表面温度不超过 140℃,测试结束静置 1 小时无复发热现象,拆解内部无大面积活性材料粉化、隔膜腐蚀破损。深度过放会永久损耗电芯容量,强制放电不合格电池使用中一旦出现电控故障极易报废甚至起火,低速电动车备电电池必须完成本项检测。


Forced Discharge Test is UN38.3 electrical abuse Item T8, simulating extreme deep over-discharge caused by wrong wiring and electronic control failure to evaluate thermal safety after over-discharge. Connect fully charged cells to standard fixed load resistance, continuously force discharge down to zero voltage and hold discharge for 90 minutes with real-time shell temperature monitoring. Deep over-discharge destroys anode SEI films, triggers massive irreversible sodium precipitation and continuous heat from internal side reactions with swelling and fire risks. Pass criteria: no combustion or explosion throughout testing, peak cell surface temperature below 140℃, no reheating within 1-hour post-test standing, and no large-area active material powdering or corroded separators after disassembly. Deep over-discharge permanently damages cell capacity. Batteries failing forced discharge easily fail or catch fire once control faults occur during operation, and backup batteries for low-speed vehicles must complete this test.


免责申明:
更多

免责声明:本文仅代表作者个人观点,与钠电池网无关。其原创性以及文中陈述文字和内容未经本网证实,对本文以及其中全部或者部分内容、文字的真实性、完整性、及时性,本站不作任何保证或承诺,请读者仅作参考,并请自行核实相关内容。涉及资本市场或上市公司内容也不构成任何投资建议,投资者据此操作,风险自担!

凡本网注明 “来源:XXX(非钠电池网)”的作品,凡属媒体采访本网或本网协调的专家、企业家等资源的稿件,转载目的在于传递行业更多的信息或观点,并不代表本网赞同其观点和对其真实性负责。

如因作品内容、版权和其它问题需要同本网联系的,请在一周内进行,以便我们及时处理、删除。 邮箱:nacells@163.com

seo seo